Does The Nec® Permit A 120-Volt Receptacle For A Gas Range To Be Connected To A Small-Appliance Branch Circuit? (2024)

1. Code Q&A: Small Appliance Circuits | EC&M

  • Jan 5, 2012 · Ex 2: A receptacle can be connected to the small-appliance branch circuit to supply a gas-fired range, oven, or counter-mounted cooking unit.

  • Your most pressing National Electrical Code (NEC) questions answered

Code Q&A: Small Appliance Circuits | EC&M

2. Electrical Circuit Requirements for Kitchens - The Spruce

  • Oct 26, 2022 · Atop your counter-top you will need two dedicated 20-amp, 120/125-volt circuits to run your small appliance loads, including devices such ...

  • Kitchens are heavy users of electricity, and code may require 5 or more circuits. Learn the standard requirements for electrical circuits in kitchens.

Electrical Circuit Requirements for Kitchens - The Spruce

3. Small Appliance Circuit Exceptions | Mike Holt's Forum

  • More results from forums.mikeholt.com

  • I have five small appliance circuits in this kitchen that I am wiring. Correct me if I am wrong, but the way I interpret the code is that I can tie the gas stove into a SA circuit, but not the exhaust fan over the stove. One would think that due to the low energy consumption of the exhaust fan...

4. a. Does the NEC permit the receptacle for the refrigerator to be... (1 Answer)

  • Mar 7, 2021 · The code permits the receptacle for the refrigerator to be connected to any one of the twoo required 20-ampere small-appliance branch circuit, ...

  • a. Does the NEC permit the receptacle for the refrigerator to be supplied by one of the required 20-ampere small-appliance branch circuits? Yes ______________________No Section _____________. b. Does the NEC permit the receptacle for the refrigerator...

a. Does the NEC permit the receptacle for the refrigerator to be... (1 Answer)

5. [PDF] NEC 2017 Code Changes Chapter 2 - Wiring and Protection

  • Additional small- appliance branch circuits shall be permitted to supply receptacle outlets in the kitchen and other rooms specified in 210.52(B)(1). No ...

6. 210.52 Dwelling Unit Receptacle Outlets - UpCodes

  • This section provides requirements for 125-volt, 15- and 20-ampere receptacle outlets. The receptacles required by this section shall be in addition to any ...

  • Explore a searchable database of US construction and building code. Code regulations are consolidated by state and city for easier navigation.

210.52 Dwelling Unit Receptacle Outlets - UpCodes

7. NEC and a Kitchen | The Garage Journal

  • Kitchen countertop receptacles, as required by 210.52(C), must be supplied by at least two 20A, 120V small-appliance branch circuits [210.11(C)(1)]. Either or ...

  • I have a long term project to untangle the work of a couple generation of previous owners. Specifically in the kitchen. There are five separate countertop receptacle circuits. Each serves a separate "logical" counter space, even though some counters are "L" shaped. Two circuits are "pure"...

8. [PDF] Section 210, NEC (2005) - Village of Schiller Park

  • Additional small-appliance branch circuits shall be permitted to supply receptacle outlets in the kitchen and other rooms specified in 210.52(B)(l). No ...

9. [PDF] BUILDING DIVISION - Mesa County

  • Mar 1, 2021 · A. Small Appliance Branch Circuits - The NEC requires a minimum of two (2), 20 amp branch circuits to feed receptacle outlets for small ...

10. [PDF] ELECTRICAL ROUGH - City of Llano

  • IGNITER FOR GAS RANGE IS PERMITTED TO BE ON SMALL APPLIANCE CIRCUIT. (210 ... ALL 120 V, 15 -20 AMP BRANCH CIRCUITS IN BEDROOMS, FAMILY ROOMS, DINING. ROOMS ...

11. Kitchen circuit questions - Fine Homebuilding

  • Apr 15, 2007 · And since this is an gas range the code specifically allows it to be served by counter top appliance circuits.And again if this is an electric ...

  • Big kitchen remodel, adding our first ever dishwasher, and buying a range that, although it’s a gas range, shows a 15 amp electrical rating.  Some questions: 1.  Should the circuit […]

12. [PDF] 9 Chapter 1 General Definitions - NFPA

  • ... small-appliance branch cir- cuits shall be provided for all receptacle outlets specified by. 210.52(B). (2) Laundry Branch Circuits. In addition to the number.

13. [PDF] Electrical Rough Inspection Checklist - Inverness-FL.gov

  • Countertop and island receptacles must be GFCI protected. ____ ____ ____ 4. Rangehood is NOT permitted to be on a small appliance circuit. Igniter for gas range ...

14. [PDF] Electrical Wiring Guide - Jefferson County

  • Missing: gas | Show results with:gas

15. [PDF] national electrical code and the 2018 international residential code

  • ... 120 volt 2-wire branch circuit; not less than 5 amperes for the next six 120 ... Where the total connected single-family range does not exceed 17 KW, a ...

16. [PDF] Non-dwelling Load Calculations

  • The load requirement for the small-appliance branch circuits is 1500 volt-amperes per circuit, as ... receptacle outlets for small-appliance branch circuits. (B) ...

17. 24 CFR § 3280.805 - Branch circuits required. - Law.Cornell.Edu

  • Missing: nec® | Show results with:nec®

  • § 3280.805 Branch circuits required.

24 CFR § 3280.805 - Branch circuits required. - Law.Cornell.Edu

18. 2020 RESIDENTIAL CODE OF NEW YORK STATE | ICC DIGITAL CODES

  • 2, a receptacle outlet to serve a specific appliance shall be permitted to be supplied from an individual branch circuit rated at 15 amperes or greater. [210.52 ...

  • ICC Digital Codes is the largest provider of model codes, custom codes and standards used worldwide to construct safe, sustainable, affordable and resilient structures.

19. [PDF] Code Calculations for Residential Installations - Electrical Association

  • on small appliance branch circuit. AND power for a gas range controls- are permitted on small appliance ckt.) 60. Page 61. ▻ (3) Kitchen Receptacle ...

20. [PDF] 2022 CALIFORNIA CODES KITCHEN, BATH & LAUNDRY ...

  • • A minimum of two 20-amp small appliance branch circuits are required to serve countertop and ... max. Receptacle. • A range hood / microwave combination can be ...

21. [PDF] Proposed North Carolina Amendments to 2020 NEC - OSFM

  • Amend NEC 2020, page 68: (2) No Other Outlets. The two or more small-appliance branch circuits specified in 210.52(B)(1) shall have no other outlets ...

Does The Nec® Permit A 120-Volt Receptacle For A Gas Range To Be Connected To A Small-Appliance Branch Circuit? (2024)
Top Articles
Latest Posts
Article information

Author: Greg O'Connell

Last Updated:

Views: 5897

Rating: 4.1 / 5 (42 voted)

Reviews: 81% of readers found this page helpful

Author information

Name: Greg O'Connell

Birthday: 1992-01-10

Address: Suite 517 2436 Jefferey Pass, Shanitaside, UT 27519

Phone: +2614651609714

Job: Education Developer

Hobby: Cooking, Gambling, Pottery, Shooting, Baseball, Singing, Snowboarding

Introduction: My name is Greg O'Connell, I am a delightful, colorful, talented, kind, lively, modern, tender person who loves writing and wants to share my knowledge and understanding with you.